Rexroth Hydraulic Motor A2fe Series with Low Price for Sale

Rexroth Hydraulic Motor A2fe Series with Low Price for Sale

CZPT hydraulic motor A2FE Series  with Low Value for sale

A2FE180 hydraulic motor new brand name manufactured in Germany
 
CZPT fastened motor A2FE28, A2FE32, A2FE45, A2FE56, A2FE63, A2FE80, A2FE90, A2FE107, A2FE125, A2FE160, A2FE180,
A2FE250, A2FE355

Description  

Open and shut circuits
Sequence 61 and sixty
Pressure:
Dimensions 28 to180 Nominal pressure 5800 psi (four hundred bar)/ Peak strain 6500 psi (450 bar)
Size 250 to 355 Nominal strain 5100 psi (350 bar)/ Peak stress 5800 psi (400 bar)
 
The A2FE fastened plug-in motor with axial tapered piston rotary team of bent-axis layout, for hydrostatic drives in open and closed circuits
-Significantly-reaching integration in mechanical gearbox due to recessed mounting flange situated in the heart of the circumstance (incredibly space-preserving development)
-The output velocity is dependent on the circulation of the pump and the displacement of the motor.
-The output torque increases with the force differential among the large-pressure and the lower-strain facet.
-Little proportions.
-Substantial total effectiveness.
-CZPT device, prepared-assembled and examined.
-Easy to put in, simply plug into the mechanical gearbox.
-No configuration requirements to be observed when installing.
 
CZPT Data 
Table of values (theoretical values, without performance and tolerances values rounded)

CZPT A2FE motor A2FE28 A2FE32 A2FE45 A2FE56 A2FE63 A2FE80  
Displacement Vg cm3 28.1 32 45.6 fifty six.1 sixty three 80.four  
Pace greatest nnom rpm 6300 6300 5600 5000 5000 4500  
nmax2) rpm 6900 6900 6200 5500 5500 5000  
Enter flow Vg qV L/min 177 202 255 281 315 362  
Torque at Vg and Dp = 350 bar T Nm 157 178 254 313 351  
Dp = four hundred bar T Nm 179 204 290 357 401  
Rotary stiffness c kNm/ rad two.ninety three 3.12 four.eighteen 5.ninety four six.twenty five eight.seventy three  
Moment of inertia JGR  kgm2 .0012 .0012 .0571 .0042 .0042 .0072  
Optimum angular a rad/s2 6500 6500 14600 7500 7500 6000  
Situation quantity V  L .two .two .33 .forty five .forty five .55  
Mass (approx.) m kg 10.five 10.5 fifteen eighteen 19 23  
Size A2FE90 A2FE107 A2FE125 A2FE160 A2FE180 A2FE250 A2FE355
Displacement Vg cm3 90 106.7 a hundred twenty five 160.four a hundred and eighty 250 355
Pace optimum nnom rpm 4500 4000 4000 3600 3600 2700 2240
nmax2) rpm 5000 4400 4400 4000 4000
Input stream qV L/min 405 427 five hundred 577 648 675 795
Torque at Vg Dp = 350 bar T 501 594 696 893 1003 1393 1978
Dp = 400 bar T 573 679 796 1571 1146
Rotary stiffness c kNm/rad 9.fourteen 11.two eleven.nine 17.4 18.2 seventy three.one 96.1
Instant of inertia JGR kgm2 .0072 .0116 .0116 .571 .571 .061 .102
Greatest angular a rad/s2 6000 4500 4500 3500 3500 10000 8300
Case quantity V L .fifty five .eight .8 1.one 1.1 two.five three.five
Mass (approx.) m kg 25 34 36 47 forty eight 82 110

CZPT fluid
Prior to starting up undertaking plHangZhou, make sure you refer to our data sheets RE 95710 (mineral oil), RE 95711 (environmentally appropriate hydraulic fluids) and RE 95712 (HFD hydraulic fluids) and RE 95713 (HFA, HFB, HFC hydraulic fluids) for detailed details concerning the choice of hydraulic fluid and software problems. The plug-in motor A2FE is not suitable for procedure with HFA hydraulic fluid. If HFB, HFC or HFD or environmentally acceptable hydraulic fluids are utilised, the limitations relating to technological knowledge or other seals should be noticed.
Particulars with regards to the selection of hydraulic fluid
The appropriate option of hydraulic fluid requires understanding of the working temperature in relation to the ambient temperature: in a shut circuit, the circuit temperature, in an open circuit, the reservoir temperature. The hydraulic fluid should be chosen so that the functioning viscosity in the working temperature assortment is inside the ideal range (νopt), see shaded spot of the assortment diagram. We recommended that the greater viscosity class be selected in each situation. Illustration: At an ambient temperature of X °C, an working temperature of sixty °C is set in the circuit. In the the best possible running viscosity variety (νopt., shaded spot) this corresponds to the viscosity courses VG 46 or VG sixty eight to be selected: VG 68.
Note: The case drain temperature, which is influenced by pressure and velocity, can be larger than the circuit temperature or reservoir temperature. At no level of the part could the temperature be higher than a hundred and fifteen °C. The temperature distinction specified underneath is to be taken into account when figuring out the viscosity in the bearing. If the over problems cannot be preserved due to severe functioning parameters, we advise the use of a flushing and enhance stress valve.
Shaft seal
Permissible stress loading the service existence of the shaft seal is influenced by the speed of the axial piston unit and the case drain pressure (circumstance stress). The mean differential stress of two bar amongst the circumstance and the ambient force could not be enduringly exceeded at standard working temperature. For a higher differential force at lowered speed, see diagram. Momentary pressure spikes (t < 0.1 s) of up to 10 bar are permitted. The service life of the shaft seal decreases with an increase in the frequency of pressure spikes.

 

Rexroth Hydraulic Motor A2fe Series with Low Price for Sale